These second-generation IsoVu probes extend the applications for isolated probe technology to the entire power system design market with a smaller size, improved ease of use, and enhanced electrical performance.
Making accurate measurements on high-speed ungrounded systems can be problematic and engineers working with wide-bandgap technologies such as SiC and GaN face difficult challenges to accurately measure and characterise devices due to the higher frequencies and switching speeds involved. By galvanically isolating the probe from the oscilloscope, IsoVu probes have completely changed how power researchers and designers make wide bandgap power measurements.
“When first introduced, the IsoVu probes represented a true breakthrough for our customers because they could gain actual insight into the performance of the high side of their half-bridge designs, eliminating a significant blind spot,” said Suchi Rinivasan , General Manager of Tektronix Mainstream Solutions. “With this second generation of IsoVU, we are making this cutting edge isolated measurement technology accessible to a broader range of customers for such tasks as product level R&D, validation and EMI troubleshooting.”
The IsoVu Gen 2 probes use patented electro-optical technologies to capture signals and power the probes without the need for an electrical connection to the oscilloscope. Compared to traditional high voltage differential probes, these probes offer a combination of high bandwidth, dynamic range and best-in-class common-mode rejection ratio (CMRR) over the probe’s full bandwidth. Non-isolated probes’ CMRR ratings derate quickly as frequency increases, making higher frequency measurements impossible. The use of optical cables also allows for long cable lengths and makes the probes largely immune to EMI.
The IsoVu Gen 2 probes offer a set of upgrades and enhancements across the board, including:
● Smaller size – At about one-fifth the size of the first generation, the TIVP Series probes make it easier to access hard to reach measurement points that were previously inaccessible. Additionally, the separate controller box has been condensed and is now self-contained inside the probe’s compensation box.
● Improved sensitivity – The new probes are more sensitive, with less noise at +/- 50V measurements for greater visibility and voltage sensitivity in wide bandgap measurements.
● Greater accuracy – The new probe offers enhanced accuracy in a number of areas including improved DC accuracy, enhanced gain accuracy over the full input range and improved temperature drift correction. These enhancements enable deeper characterization of wide bandgap designs for increased energy efficiency.
● Less tip swapping – With wider dynamic range at the sensor head, fewer tips are required to cover the same voltage range as IsoVu Gen 1. This shortens the time needed to perform device testing, eliminates potential errors when swapping tips, and lowers the cost for customers that needed to purchase multiple tips on IsoVu Gen 1.